Digiplex EVO641R Installation Manual

Browse online or download Installation Manual for Security access control systems Digiplex EVO641R. Digiplex EVO641R Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
We hope this product performs to your complete satisfaction. Should you have any
questions or comments, please visit www.paradox.com and send us your comments.
High Security and Access System
EVO48 V1.2
EVO192 V1.2
Programming Guide
Includes LCD Keypad
Programming
Page view 0
1 2 3 4 5 6 ... 67 68

Summary of Contents

Page 1

We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your

Page 2 - Hardware Differences

Digiplex -EVO- - 10 - Programming GuideZone InformationZone ProgrammingZone Description Module 8-digit Serial Number Input# Define Assign Zon

Page 3 - Entering Programming Mode

Digiplex -EVO- - 11 - Programming Guide38__________________________________________ _______________ ___/___/___/___/___/___/___/___ ___/___/__

Page 4 - Serial Number List

Digiplex -EVO- - 12 - Programming Guide79__________________________________________ _______________ ___/___/___/___/___/___/___/___ ___/___/__

Page 5

Digiplex -EVO- - 13 - Programming Guide120__________________________________________ _______________ ___/___/___/___/___/___/___/___ ___/___/_

Page 6

Digiplex -EVO- - 14 - Programming Guide161__________________________________________ _______________ ___/___/___/___/___/___/___/___ ___/___/_

Page 7

Digiplex -EVO- - 15 - Programming GuideZone report codesZone #Alarm Report CodesAlarm Restore Report CodesTamper Report CodesTamper Restore Re

Page 8

Digiplex -EVO- - 16 - Programming Guide85 __/__ __/__ __/__ __/__ 130 __/__ __/__ __/__ __/__86 __/__ __/__ __/__ __/__ 131 __/__ __/__ __/__

Page 9 - Zone Programming

Digiplex -EVO- - 17 - Programming GuideZone Labels175 __/__ __/__ __/__ __/__ 184 __/__ __/__ __/__ __/__176 __/__ __/__ __/__ __/__ 185 __/__

Page 10 - Zone Information

Digiplex -EVO- - 18 - Programming Guide91__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__126__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__161_

Page 11

Digiplex -EVO- - 19 - Programming GuideKeyswitch ProgrammingKeyswitch Description Module Section 8-digit Serial Number Input# Section Define

Page 12

Digiplex -EVO- - 2 - Programming GuideNew Remote Control ProgrammingHardware RequirementsHardware DifferencesThe programming for the EVO48 and

Page 13

Digiplex -EVO- - 20 - Programming GuideKeyswitch Arming/Disarming Report CodesAdemco slow, Silent Knight fast, SESCOA, Ademco express or Pager

Page 14

Digiplex -EVO- - 21 - Programming GuideProgrammable OutputsPGM Test ModePGM DelayPGM OptionsIn order to use the Flexible PGM Deactivation O

Page 15 - Zone report codes

Digiplex -EVO- - 22 - Programming Guide004 Non-reportable Event000Smoke detector reset 001 001Arm with no entry delay 002 002Arm in Stay mode

Page 16

Digiplex -EVO- - 23 - Programming Guide013 Disarm with Master000 User Codes 001 to 255 001 to 255 001 to 255001 User Codes 256 to 511 000 t

Page 17 - Zone Labels

Digiplex -EVO- - 24 - Programming Guide029 Late to Disarm by User000 User Codes 001 to 255 001 to 255 001 to 255001 User Codes 256 to 511 000

Page 18

Digiplex -EVO- - 25 - Programming Guide040Fail to Communicate on Telephone Number000 Telephone Number 001 to 004 001 to 004255 Any telephon

Page 19 - Keyswitch Programming

Digiplex -EVO- - 26 - Programming Guide064 Status 1See Note 1on page 27Armed 000 000Force Armed 001 001Stay Armed 002 002Instant Armed 003 003

Page 20

Digiplex -EVO- - 27 - Programming GuideNOTE 1: 000 = Occurs in all partitions enabled in the system (see section [3031]).001 = Partition 1

Page 21 - Programmable Outputs

Digiplex -EVO- - 28 - Programming GuideInput SpeedsInstaller Code ProgrammingSection Data - Decimal Value (001 - 255) Description Default[0961

Page 22

Digiplex -EVO- - 29 - Programming GuideUser Code OptionsSections [1001] to [1999]The instructions that follow detail how to program access

Page 23

Digiplex -EVO- - 3 - Programming GuideTable of ContentsThings You Should KnowAbout This Programming GuideThis programming guide should be u

Page 24

Digiplex -EVO- - 30 - Programming GuideArming and Disarming Report CodesAdemco slow, Silent Knight fast, SESCOA, Ademco express or Pager forma

Page 25 - † Not Used Not Used

Digiplex -EVO- - 31 - Programming GuideAccess Control SectionsAssigning a Door to the SystemThese doors are used to program the Access Leve

Page 26

Digiplex -EVO- - 32 - Programming GuideSchedule ProgrammingEach Schedule determines when users are permitted access. Schedules 001 to 015 (sec

Page 27

Digiplex -EVO- - 33 - Programming GuideThe Start and End Time of a schedule cannot cross over into another day. For example, to program a s

Page 28 - Installer Code Programming

Digiplex -EVO- - 34 - Programming GuideBackup SchedulesEach programmed schedule (see Schedule Programming on page 32) can be backed up or link

Page 29 - User Code Options

Digiplex -EVO- - 35 - Programming GuideKeypad NumberingSections [2801] to [2832] are used solely for the purpose of identifying a keypad in

Page 30 - Disarming Report Codes

Digiplex -EVO- - 36 - Programming GuideControl Panel SettingsDAYLIGHT SAVINGS TIME SCHEDULESystem Options = Default setting* Please note that

Page 31 - Access Control Sections

Digiplex -EVO- - 37 - Programming Guide = Default setting*This option is used by some event monitoring software such as Hyperterminal. Wit

Page 32 - Schedule Programming

Digiplex -EVO- - 38 - Programming GuideDialer Options = Default settingOther OptionsSECTION [3036]: Dialer Options 1 SECTION [3037] : Dialer

Page 33 - SECONDARY SCHEDULES

Digiplex -EVO- - 39 - Programming GuideSchedule Tolerance WindowCommunication SettingsAccount NumbersOnly the SIA format supports the [0] =

Page 34 - Holiday Programming

Digiplex -EVO- - 4 - Programming GuideSerial Number List Module Type, Serial Number & Details Module Type, Serial Number & Details Mod

Page 35 - Remote Control Programming

Digiplex -EVO- - 40 - Programming GuideReporting FormatsFor North American installations using either SIA or Contact ID reporting formats, ent

Page 36 - System Options

Digiplex -EVO- - 41 - Programming GuideVDMP3 Voice ModuleProgram up to 8 telephone numbers which the VDMP3 will call in sequence in the cas

Page 37

Digiplex -EVO- - 42 - Programming GuidePartition SettingsAuto-Arm TimesArming Report Schedules (If partition is armed outside schedule, the pa

Page 38 - Other Options

Digiplex -EVO- - 43 - Programming GuidePartition TimersPartition Options 1Description Partition 1 Partition 2 Partition 3 Partition 4 Partitio

Page 39 - Communication Settings

Digiplex -EVO- - 44 - Programming GuidePartition Arming / Disarming OptionsSECTION [3421] : Partition 4 SECTION [3521] : Partition 5 SECTION [

Page 40 - Reporting Formats

Digiplex -EVO- - 45 - Programming GuidePartition Panic Alarm OptionsPartition Bell Squawk OptionsPartition One-Touch Options* If a keypad is a

Page 41 - VDMP3 Voice Module

Digiplex -EVO- - 46 - Programming GuidePartition Special OptionsPartition Arming / Disarming Event Call DirectionPartition Alarm / Alarm Resto

Page 42 - Partition Settings

Digiplex -EVO- - 47 - Programming GuidePartition Tamper / Tamper Restore Event Call DirectionSpecial Arming Exit DelayNo Movement ScheduleThe

Page 43 - Partition Options 1

Digiplex -EVO- - 48 - Programming GuideSpecial and Trouble Report CodesAdemco slow, Silent Knight fast, SESCOA, Ademco express or Pager format

Page 44

Digiplex -EVO- - 49 - Programming GuideOther Settings and ModesParadox Memory Key (PMC-5)[3966] __/__ Phone Number 2 Fail to Communicate [3

Page 45 - Partition One-Touch Options

Digiplex -EVO- - 5 - Programming Guide49:_____________________________________ 62:_____________________________________ 75:___________________

Page 46 - Partition Special Options

Digiplex -EVO- - 50 - Programming GuideDownload Memory Key to Control Panel.1) Insert the Memory Key (PMC-5) onto the control panel’s connecto

Page 47 - No Movement Schedule

Digiplex -EVO- - 51 - Programming GuideInstaller Function KeysTo access the installer functions, press and hold the [0] key, enter the [INS

Page 48

Digiplex -EVO- - 52 - Programming GuideCancel Alarm with PC Software 1 4A6 - Cancel OR - Disarm From AlarmVoice Disarm 1 4A7 - Remote arm/disa

Page 49 - Other Settings and Modes

Digiplex -EVO- - 53 - Programming GuideContact ID Report Code ListIf using the Ademco Contact ID format, key in the 2-digit hexadecimal val

Page 50 - Software Reset

Digiplex -EVO- - 54 - Programming GuideSYSTEM TROUBLES - 300 & 310 378 Cross-Zone Trouble 6D 458 User on Premises A1300 System Trouble 39

Page 51 - Automatic Report Code List

Digiplex -EVO- - 55 - Programming GuideVDMP3 Installation InstructionsVDMP3 Installation InstructionsVDMP3 Setup InstructionsStepEVO sectio

Page 52 - Default SIA Report Code

Digiplex -EVO- - 56 - Programming GuideLCD Keypad ProgrammingThe keypad’s serial number can be found on the keypad’s PC board. The keypad’s se

Page 53 - Contact ID Report Code List

Digiplex -EVO- - 57 - Programming Guide† Section/option is only available with LCD keypad with reader.‡ Section/option is only available wi

Page 54

Digiplex -EVO- - 58 - Programming Guide Table 2: Message Programming Special Function Keys Table 3: Alphanumeric Keys Table 4: Special Char

Page 55 - Feature Activation (PGMs)

Digiplex -EVO- - 59 - Programming GuideUsing the Memory KeyDownload Contents of the Memory Key to the LCD Keypad1) Insert the Memory Key on

Page 56 - N Disabled

Digiplex -EVO- - 6 - Programming Guide101:____________________________________ 114:____________________________________ 127:__________________

Page 57 - [018]: Beeping Assignment*

Digiplex -EVO- - 60 - Programming GuideAccess Control Connections (EVO641R only)EVO641REVO641RFused external power supply (recommended)EVO641R

Page 58 - Message Programming

Digiplex -EVO- - 61 - Programming GuideControl Panel Hardware ConnectionsSingle Zone InputsATZ - Double Zone Inputs

Page 59 - Combus Voltmeter

Digiplex -EVO- - 62 - Programming GuideConnectionsAs indicated in Table 6 on page 64, this run of wire can support 700mA. Total mA on this run

Page 60 - BLK and Z2 terminals

Digiplex -EVO- - 63 - Programming GuideTelephone Line Connections Table 5: Milliamp Consumption TableSTEP 1: Using Table 5, calculate the

Page 61 - ATZ - Double Zone Inputs

Digiplex -EVO- - 64 - Programming GuideSTEP 2: If the Grand Total is less than 700mA, go to step 3. If the value is greater, you will require

Page 62 - Connections

Digiplex -EVO- - 65 - Programming GuidePCB LayoutRefer to the UL and ULC Warnings section of the EVO Reference & Installation Manual fo

Page 63 - Telephone Line Connections

Digiplex -EVO- - 66 - Programming GuideNotes__________________________________________________________________________________________________

Page 64 - Built-in RTC

WarrantyFor complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Y

Page 65 - PCB Layout

Trouble DisplayTo view the Trouble Display on LCD or LED keypads:1) Press the [TRBL] key.2) For LEDs: Press the Numerical Symbol corresponding to the

Page 66

Digiplex -EVO- - 7 - Programming Guide153:____________________________________ 166:____________________________________ 179:__________________

Page 67 - Limitations of Alarm Systems

Digiplex -EVO- - 8 - Programming Guide205:____________________________________ 218:____________________________________ 231:__________________

Page 68 - Trouble Display

Digiplex -EVO- - 9 - Programming GuideZone ProgrammingEnter Section [0400], then enter the number of the zone you want to programEnter the