LCD Keypad V2.0DGP2-641BLReference and Installation ManualDGP-641DGP2641-EI14.fm Page -3 Monday, February 20, 2006 9:35 AM
6 Reference & Installation Manualsource’s data. If you want to program more than one keypad with the source’s data, enter the serial numbers of th
Digiplex LCD Keypad 7n3.6 Copy the Keypad Contents to the Memory KeySection [520]1. Insert the memory key onto the keypad’s connector labelled “KEY” (
8 Reference & Installation Manual4.0 System Options4.1 Partition AssignmentSection [001]: Options [1] to [8]Each keypad in the system can be assig
Digiplex LCD Keypad 9n4.4 Display Entry Delay TimerSection [003]: Option [3]Based on the user's needs, an Entry Delay Timer will be programmed to
10 Reference & Installation ManualFigure 4.1: LCD Screen4.6 Confidential Mode TimerSection [007]Section [007] determines the amount of time withou
Digiplex LCD Keypad 11n4.8 MutingSection [004]: Option [1]The keypad can be programmed not to emit audible sounds, including Chimed zones. During Muti
12 Reference & Installation Manual4.11 Beep on TroubleSection [005]: Options [1] to [4]Potential troubles have been sorted into groups. With these
Digiplex LCD Keypad 13n4.13 Combus VoltmeterThe combus Voltmeter provides a real-time display of the voltage so you can verify if the bus is supplying
14 Reference & Installation Manual5.0 Programmable Output Options5.1 PGM StateSection [006]: Option [1]The keypad's on-board PGM can be set a
Digiplex LCD Keypad 15n5.3 PGM Base TimeSection [006]: Option [3]If the keypad's on-board PGM is set in PGM Timed Mode (see section 5.2 on page 1
DGP2641-EI14.fm Page -2 Monday, February 20, 2006 9:35 AM
16 Reference & Installation Manual5.6 PGM Activation EventSections [009] to [012]The PGM Activation Event determines which event will activate the
Digiplex LCD Keypad 17n6.0 Message ProgrammingSections [101] to [148], [200] to [204], and [301] to [396]Each section contains one message with a maxi
18 Reference & Installation ManualTable 6.1: Message Programming Keys6.1 Special Function Keys[STAY] - Insert SpacePressing the [STAY] key inserts
Digiplex LCD Keypad 19n[BYP] - Lower Case / Upper CaseEvery time the [BYP] key is pressed it will toggle the case setting from lower to upper case and
20 Reference & Installation ManualTable 6.2: Special Characters CatalogDGP2641-EI14.fm Page 20 Monday, February 20, 2006 9:35 AM
Digiplex LCD Keypad 21nWarrantyParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship und
NotesDGP2641-EI14.fm Page 22 Monday, February 20, 2006 9:35 AM
DGP2641-EI14.fm Page 23 Monday, February 20, 2006 9:35 AM
For technical support in Canada or the U.S., call 1-800-791-1919 for English or 1-866-912-0600 for French, Monday to Friday from 8:00 a.m. to 8:00 p.m
Table of ContentsIntroduction... 1Specifications ...
Confidential Mode Timer ... 10Time Display Option ... 10Muting...
Digiplex LCD Keypad 1n1.0 IntroductionThank you for choosing Paradox Security Systems. Digiplex security systems offer advanced technology and provide
2 Reference & Installation Manual2.0 InstallationThe LCD keypad (DGP2-641BL) is connected to the control panel's combus in a star and/or dais
Digiplex LCD Keypad 3n2.2 Programmable OutputEach keypad has one on-board PGM. A PGM is a programmable output that switches to its opposite state (i.e
4 Reference & Installation Manual3.0 ProgrammingTo program the DGP2-641BL keypad, enter Module Programming Mode and then enter the desired section
Digiplex LCD Keypad 5nserial number is located on the keypad's PC board or enter section [000] in Step 3 to view the keypad’s serial number.3.2 P